显示标签为“centrifugal blower”的博文。显示所有博文
显示标签为“centrifugal blower”的博文。显示所有博文

2017年3月6日星期一

Installation and Maintenance of High Temperature Fan by Xianrun Blower

Installation and Maintenance of High Temperature Fan by Xianrun Blower


Introduction


High temperature fan is widely used in iron and steel plant, metallurgy industry, chemical industry, electric power plant and other industries, and compared with normal centrifugal fan, high temperature fan has higher failure rate, and shorter service life. So, the installation and maintenance technical requirements is relatively higher, as well as more difficult.
High Temperature Fan for Cement Rotary Kilns


1.1 Centrifugal Fan Main shaft Installation 

Thermal expansion of the high temperature fan main shaft is achieved by the positioning end bearing axial direction moving. The main shaft thermal expansion under high temperature working condition has been considered during the designation, generally, the installation location dimension of bearing house and centrifugal fan impeller will be marked clearly in the drawing. 
High Temperature Fan for Cement Rotary Kilns

During on-site installation, the below two points needs attention: 

(1) according to the main shaft expansion direction, select the load end as positioning end;

(2) according to the cover difference to confirm locating bearing and non - locating bearings.

2017年2月28日星期二

High Temperature Centrifugal Fan by Xianrun Blower

High Temperature Centrifugal Fan by Xianrun Blower

The high-temperature centrifugal fan consists of the motor, the variable speed device, the centrifugal fan body, the inlet flow control device, the slow-moving device and lubrication system.

1. the motor: generally, it is high temperature motor.
2. the variable speed device: generally, using hydraulic coupling, SCR cascade frequency control and frequency control, speed ratio is more than 2: 1.
High Temperature Fan for Cement Rotary Kilns
3. the centrifugal fan body: mainly includes the rotor group (mainshaft, impeller), casing and air inlet. The rotor is key component of centrifugal fan, so it must be processed with non-destructive inspection strictly and high-precision dynamic balance test to ensure the centrifugal fan smooth operation.

4. inlet flow control device: controlling the airflow by the adjusting door and electric actuator.
5. slow-moving device: composed of motor and high-speed ratio gear box, to ensure the rotor won't bend when the high-temperature fan stop operation.
High Temperature Fan for Cement Rotary Kilns

2017年2月23日星期四

Centrifugal Fan Application for Gas System of Iron and Steel Plant

Centrifugal Fan Application for Gas System of Iron and Steel Plant by Xianrun Blower

Centrifugal fans are widely applied in iron and steel plant gas system, and play an important part in steel plant development. 

In general, iron and steel plant generates three kinds by-product coal gas, blast furnace gas, converter gas, coke oven gas, these three gas are important energy to steel industry. While the three gas have different features. 
High Pressure Blowers for Smelting Furnace
1. Blast Furnace Gas
Blast furnace gas are produced in blast furnace process, large capacity, low calorific efficiency. At present, blast furnace dust collector in dry method is very common, compared with wet dust collection, the condensate water of blast furnace gas has stronger acidity. 

2. Converter Gas
Converter gas are produced in converter steelmaking process, high content CO, high toxicity. 
High Pressure ID Fans for Smoke or Air
3. Coke Oven Gas

Coke oven gas is generated in coke oven smelting process, has the features of high calorific efficiency, easy to explosive, high content of impurities and so on. 

2017年2月13日星期一

Centrifugal Fan Selection Matters Need Attention by Xianrun Blower---Part 2

Centrifugal Fan Selection Matters Need Attention by Xianrun Blower


5. In the centrifugal fan selection, the most important is long-term economic operation quality and efficiency, other than one-time investment. 

6. In the centrifugal fan selection, be seriously compared with each other, give preference to higher efficiency, samller size, lighter weight, larger adjusting range one. 
High Quality ID Fan for Ventilation
7. For the frequency conversion centrifugal fan, please note that the system calculated total pressure losses are rated pressure, and centrifugal fan power needs to append 15%~20% on calculated value. 

8. Pay attention to the matching relation of pipe system resistant characteristics and centrifugal fan characteristics. For stable operation, centrifugal fan needs to work around the highest efficiency point, and the working point is right of the pressure peak point in the performance curve (in larger airflow side, in general, the working pressure is 80% of pressure peak point). 

Centrifugal fan design point efficiency should not be less than 90% of the highest efficiency. 
High Temperature Fan for Cement Rotary Kilns
9. For more than one centrifugal blowers working in parallel or in series, it is better to select the same model centrifugal fans. 

2017年1月11日星期三

Abandoned Power Plant Becoming Science Fiction Movies Location by Xianrun Blower

Abandoned Power Plant Becoming Science Fiction Movies Location by Xianrun Blower

Custom Heavy Duty Industry Fans for Power Plant
This coal fired power plant came into use since the year of 1920, owned by Exelon Generation, one energy company. In 1985, after working 65 years, the power plant was out of service. And the waste machines in this power plant got rusty heavily, so there was a special beauty in this power plant. 
Custom Heavy Duty Industry Fans for Power Plant
This power plant was established after World War I. At first, it was a shipyard in 19 century, covering about 16 acre (About 6.5 hektare), part buildings under the water. Main buildings included several large sky window, 350 thousand square foot (about 0.3 hektare), and 55 foot (about 16.7 meter) height ceiling, this power plant looked most magnificent. 
High Capacity Double Suction Fans for Power Plant
Although this place was very old and shabby, Bart Blatstein and Joseph Volpe were still willing to pay about 3 million USD to buy this waste power plant, which included 1000 foot (about 300 meter) river and wharf. The two buyers planed to develop this place to hotel, banquet hall and restaurant. 
High Capacity Double Suction Fans for Power Plant

2017年1月8日星期日

Abandoned Power Plant Becoming Science Fiction Movies Location by Xianrun Blower

Abandoned Power Plant Becoming Science Fiction Movies Location by Xianrun Blower

New Design FD Fans for Boilers
According to Daily Mail reported, Bob Thissen, a photographer based in Netherlands, took the pictures of abandoned power plant inner scene, which is located in Philadelphia, America. 
New Design FD Fans for Boilers
Since the power plant shut down 30 years ago, many film makers were attracted to this place by its reputation as a scenic location, and many movies were shooted in this rusting power plant, such as Transformers, Twelve Monkeys, The Last Airbender by M. Night Shyamalan. 
High Capacity Double Suction Fans for Power Plant

2017年1月4日星期三

Xianrun Blower Cement Kiln High Temperature Centrifugal Fan

Xianrun Blower Cement Kiln High Temperature Centrifugal Fan

The Reason of Centrifugal Fan Impeller Ash Deposition


The main reason of the centrifugal fan impeller ash deposition is that, when the waste exhaust flow through the impeller, a large number of fine dust particles collide with impeller non-working surface and blade trailing edge near the working face in impeller, then deposite in the centrifugal fan impeller; what's more, dust particles are more sticky under high temperature, so the deposition chance increase. 
High Temperature Fan for Cement Rotary Kilns

Thus, the waste exhaust gas temperature and airflow speed play an important role in the ash deposition process, when the exhaust temperature of the cement kiln preheater reach over 300 centigrade degrees, then high temperature centrifugal fan will begin to happen dust deposition and crust frequently.
High Temperature Fan for Cement Rotary Kilns

2016年12月7日星期三

How to Confirm the Centrifugal Fan Outlet Angle? ---Xianrun Blower

How to Confirm the Centrifugal Fan Outlet Angle? ---Xianrun Blower


From the motor side to look the centrifugal blower, 

1. If the centrifugal fan impeller clockwise rotation, it is right. The air outlet towards to the left horizontally: right 0, the angle changes along the clockwise direction. 

2. If the centrifugal fan impeller anti-clockwise rotation, it is left. The air outlet towards to the right horizontally: left 0, the angle changes along the anti-clockwise direction. 
Coupling Driving FD Fan with High CFM


2016年11月28日星期一

Centrifugal Fan Driving Modes Advantages and Disadvantages By Xianrun Blower

Centrifugal Fan Driving Modes Advantages and Disadvantages By Xianrun Blower

A Mode: Direct Driving
The impeller of centrifugal fan connects to the motor shaft directly, this is suitable for small airflow and pressure centrifugal blower. 
Advantage: saving the parts (such as belt pulley, belt, coupling, etc.), reliable performance.
Disadvantage: fixed speed. 
High Quality ID Fan for Ventilation
C Mode: Belt Driving
The impeller connects to motor shaft by belt pulley.
Advantage: adjustable speed, motor installation position is flexible. 
Disadvantage: Some parts are easy to break down, and need updating maintenance. 
High Temperature Fan For Metallurgical Factory
D Mode: Coupling Driving
The impeller connects to motor shaft by coupling, coupling drive centrifugal fan for high temperature, large airflow and high pressure condition. 
Advantage: stable operation, high efficiency. 
Disadvantage: fixed speed, high cost.
Wear Resistant ID Fan

2016年11月27日星期日

Venturi Scrubber Dust Collector Centrifugal Fan by Xianrun Blower

Venturi Scrubber Dust Collector Centrifugal Fan by Xianrun Blower

The venturi scrubber is mainly composed of venturi tube (shrink tube, throat pipe, expanding tube) and the cyclone separator, centrifugal fan. 
Custom heavy Duty Industry Fan from China Supplier
Working principle of venturi scrubber dust collector: dusty gas enters into the shrink tube, then the flow speed increases gradually along the pipe; water or other liquid are ejected by the throat pipe, struck by high-speed airflow and atomization; dust particles in the gas contact with liquid drops and lubricate; after entering expanding pipe, the flow speed decreases gradually; the dust particles are bonded to each other; the particles volume increase and easy to remove; then, the gas enters the cyclone separator, due to the centrifugal force, water and dust particles are thrown to the separator wall and outflow cyclone separator; finally, the purified gas is exhausted out by centrifugal fan. 
Large Airflow Backward Curved Fans
The advantage: simple structure, high dusting efficiency, good cooling effect. 
The disadvantage: big resistance, just used for wet-type dust collecting.
High Quality ID Fan for Ventilation

2016年11月23日星期三

Spray Tower Scrubber Centrifugal Fan by Xianrun Blower

Spray Tower Scrubber Centrifugal Fan by Xianrun Blower

Spray Tower Scrubber Working Principle: 

In the counter-current spray tower, dusty gas moves upward by centrifugal fan, the droplets by nozzle make downward movement. Because of inertia collision, intercept, cohesion functions between droplets and dust particles, the larger particles are collected by the droplets. 
High Temperature Fan For Metallurgical Factory

Spray Tower Scrubber Features:

1. It uses packed tower to purify the waste gas, and is suitable for continuous or intermittent dusty gas discharge. 
2. Spray tower scrubber has the features of simple structure, small pressure loss, stable operation, high efficiency, etc.
3. Wide application, and can purify a variety of pollutants and dusty gas.
Custom heavy Duty Industry Fan from China Supplier

Spray Tower Scrubber Application:

In chemical industry, electronics industry, metallurgic industry, electroplating industry, textile factory, food plant, and so on, it can purify and collect acid waste gas, alkaline waste gas, dusty gas in the processing. 
Large Airflow Backward Curved Fans

2016年11月21日星期一

Gravitational Dust Collector Centrifugal Fan by Xianrun Blower

Gravitational Dust Collector Centrifugal Fan by Xianrun Blower

Dust removal principle: the centrifugal fans of gravitational dust collector reduce gas speed and change flow direction suddenly; larger dust particles separate from gas under the function of gravity and inertia force; settle to the dust collector cone bottom.
Industrial Exhaust Fans
The gravitational dust collector belongs to the coarse dust removal. There is intercepter valve in gravity precipitator upper part, ash discharging gear in gravity precipitator bottom part. Gravity dust collector is according to dust gravity sedimentation, to separate dust from the dirty gas.
Custom heavy Duty Industry Fan from China Supplier
The process is that the gas enters into dust collector from the horizontal direction, under the gravity force, dust particles settling down gradually, and gas moving forward along the horizontal direction by centrifugal fan, the smaller dust particles settling down, so as to achieve dust collecting aim.
Custom heavy Duty Industry Fan from China Supplier

2016年11月15日星期二

Cartridge Dust Collector Centrifugal Fan By Xianrun Blower

Cartridge Dust Collector Centrifugal Fan By Xianrun Blower

Cartridge Dust Collector Working Principle 

Under the function of the main centrifugal fan, dusty gas from cartridge dust collector bottom air inlet enters into the bottom chamber for dusty gas pretreatment, and then into the upper chamber; dust adsorb in the outer surface of filter cartridge, the clean gas after filtration through the cartridge enters into the net gas chamber of upper box, then come together to the outlet and exhausted out. 
Custom heavy Duty Industry Fan from China Supplier
With filtering continuing, the dust accumulated on the filter cartridge surface will be more and more, accordingly, it will increase equipment running resistance. In order to ensure the system normal operation,  the cartridge dust collector resistance should be no more than 1400 ~ 1600 Pa, when the resistance is over the limit range, PLC pulse automatic controller issue instructions by resistance or timing, to clean dust. 
Industrial Exhaust Fans
The cartridge dust collector cleaning process is to cut off one chamber purified gas air outlet firstly, to keep the airflow in stationary state; then compress air pulse back blow dedusting; after a while natural sedimentation, open the chamber's chamber purified gas air outlet again; not only clean out the dust completely, also avoid secondary dust adsorption produced by pulsate dust extraction; so clean the dust of other chamber one by one.
High Temperature Fans for Dust Collecting

2016年11月14日星期一

Electrostatic Dust Collector Centrifugal Fan by Xianrun Blower

Electrostatic Dust Collector Centrifugal Fan by Xianrun Blower

Working principle of electrostatic precipitator:

Gas containing dust particles, the centrifugal fan sends them go through the high voltage electric field formed by cathode lines (discharge electrode) and anode lines, cathode lines wiring high voltage dc power and anode lines wiring grounding, due to the cathode makes corona discharge, then the gas is ionized. 
High Temperature Fans for Dust Collecting
At this point, the negatively charged gas ions, under the electric field force, move to anode plate; collide with the dust particles during the movement; make the dust load with negative charge, in the same way, the charged dust particles also move to the anode plate, releasing the electronic after arriving the anode; finally dust deposition on the anode plate, and the purified gas is exhausted out the dust collector by centrifugal fan.
Wear Resistant ID Fan

Electrostatic Dust Collector Wide Application: 

All kinds mill machines in cement plant, chemical fertilizer factory, and so on, dealing with spread source for crushing machines, packaging machines and dryers, etc.
Large Airflow Backward Curved Fans

2016年11月11日星期五

Cyclone Dust Collector by Xianrun Blower

Cyclone Dust Collector by Xianrun Blower

Cyclone Dust Collector Working Principle: 

the dusty gas from the inlet by centrifugal fan enter to dust collector; air flow makes rotational motion; upper and lower spiral airflow split into twin twist worm movement; the dust separate strongly in the twin twist worm boundary;
coarser dust particles move to the outer wall by centrifugal force, and drop to dust collector bottom with external rotating. 
High Temperature Fans for Dust Collecting
Upper spiral airflow gather fine particle dust, thus improving the dust collector efficiency. The fine dust particles are brought to top by upper spiral airflow, enter into by-pass separation chamber with upper spiral airflow; is induced to dust collector by return air outlet and join in the internal air flow; the purified air is exhausted out by exhaust fan; the isolated dust drop into the hopper.
Wear Resistant ID Fan

Cyclone Dust Collector Advantages:

(1) No moving parts inside the cyclone dust collector, and easy maintenance;
(2) Convenient production and management;
(3) To deal with the same air volume, the cyclone dust collector has, smaller volume, simpler structure, lower price;
(4) As preliminary dust collector, the cyclone dust collector can be installed vertically, and easy to use;
(5) To deal with large air volume, more than one parallel installation is convenient, and the efficiency has not affected;
(6) The cyclone dust collector is resistant to 400 centigrade high temperature, if use special high temperature resistant material, it can tolerate higher temperature;
(7) If the cyclone dust collector have wear-resisting lining, it can be used to purify the flue gas containing abrasive dust;
(8) The dust collector can clean dust by dry method, so in favor of recycling valuable dust.
Industrial Exhaust Fans

2016年11月10日星期四

Bag Dust Collector Centrifugal Fan by Xianrun Blower

Bag Dust Collector Centrifugal Fan by Xianrun Blower

Dust collector is mainly composed of upper box, middle box, air inlet pipe, ash bucket, centrifugal fan, filter bag, discharge device, etc. 
Industrial Exhaust Fans
Bag dust collector working principle: dusty gas enters into filter chamber from bottom open flange; coarser particles drop into ash bin directly; dusty gas is filtrated by the bag filter; dust is retained in bag, pure air go to the gas chamber, exhausting out by centrifugal fan.

Custom heavy Duty Industry Fan from China Supplier
When the dust on the bag filter surface increases, the equipment resistant reach the definitive pressure, programmer controller begins to work, then open pulse valve one by one. The compressed air from centrifugal fan blow and clean the dust bag through the spout; filter bag balloons suddenly; under the action of reverse flow, the dust breaking away from filter bag and drops to ash bin quickly, finally, the dust is discharged by cindervalve. 

High Pressure Blowers for Smelting Furnace
This type bag dust collector is widely applied in metallurgy, casting, building material, mining, and chemical industry, etc.

2016年11月9日星期三

Cement Raw Material Mill Recirculation Fan by Xianrun Blower

Cement Raw Material Mill Recirculation Fan by Xianrun Blower

Raw material mill recirculation fan plays a big role in cement raw material mill system, it can control the following parameters of mill system by adjusting the circulation fan:
Industrial Fans and Blowers for Cement Plant
1. Airflow in raw material mill: vertical mill is swept by the wind, so needs appropriate air volume. If air flow is insufficient, qualified raw material can not be taken out by recirculation centrifugal fan timely; material layer thickness will increase; slag discharge quantity increase; equipment load is high; so output decrease. While if the air volume is too large, material layer thickness will be too thin to influence the raw material mill the stability operation. 
Industrial Fans and Blowers for Cement Plant
2. Material layer thickness: material bed stable operation is important to vertical mill stable operation. Only material layer is stable, air volume, air pressure and feeding volume can be stable. Otherwise it needs to adjust airflow and feeding volume to maintain material thickness. Improper adjustment will cause shock, motor load rise or system tripping, etc. 
3. Mill vibration: vibration is ubiquitous in ring-roller mill working, if the vibration is too large, will cause mechanical damage of mill plates, roller and lining plate. 
Industrial Fans and Blowers for Cement Plant
4. Pressure difference in mill: pressure difference refers to the pressure loss in centrifugal fan vane. During mill operation, grinding mill load has changes, not only on the electric current, material thickness, and vibration amplitude, but also the pressure difference. 
5. Mill outlet temperature: recirculation centrifugal fan can control outlet temperature effectively, what is more, it can keep good drying and grinding operation conditions. 
6. Product fineness: recirculation centrifugal fan air volume also has a certain influence on the size of the fineness.