Fan maintenance is a skill what technical personnel must master, and it is necessary to understand the whole structural features of centrifugal fan.
As for the high capacity centrifugal fan with double supporting, inlet box is necessary.
double suction industrial centrifugal fan |
Inlet end of inlet box is connected to the air duct system; the intermediate shaft of inlet box is placed in the intermediate shaft enclosure;
the half coupling of motor side is protected by coupling guard; the whole inlet box is fixed on the foundation.In order to reduce the fan noise,inlet box can be equipped with silencer.
high capacity centrifugal fan |
The fan casing is welded structure, the upper cover of fan casing can be removed, for the convenient to disassembling and maintenance of the impeller.
Main bearing box supporting impeller is linked with the second half of the cover by bolts, and centring through the flange.