Ring Blower Tubing and Wiring Matters by Xianrun Blower
Ring Blower Tubing
Tubing to the air inlet and outlet, please keep the same center, do not connect them reluctantly.The tube weight should not directly on the high pressure blower.Xianrun Blower High Pressure Blower |
Ring Blower Wiring
1. Please use the fixed voltage and frequency as the label, and assemble the correct line according to the wiring diagram;2. The change of voltage should be within 5% of fixed voltage. 10% is OK, but it is easy to break down during the long time, so better to avoid that;
3. There is no thermal overload protection device in high pressure blower, so please install the same power over load protection switch, and adjust the same value of safety current;
Xianrun Blower High Pressure Ring Blower |
5. Confirming the rotation direction firstly. After the wiring, turn on the switch to confirm whether the rotation direction is the same as arrow and whether there is noise. Wrong rotation direction will reverse air suction and blowing order. If the ring blower is three-phase, change any two wiring among three external wiring;
6. To prevent electric leakage, ground lead is necessary.
Xianrun Blower High Pressure Ring Blower |
没有评论:
发表评论