显示标签为“ventilation fan”的博文。显示所有博文
显示标签为“ventilation fan”的博文。显示所有博文

2016年11月29日星期二

Xianrun Blower Provides Large Centrifugal Fans for 5000t/d Cement Production Line

Xianrun Blower Provides Large Centrifugal Fans for 5000t/d Cement Production Line

Industrial Fans and Blowers for Cement Plant
Item
Centrifugal Fan Category
Unit
Quantity
1
Raw Material Grinding Mill Exhaust Fan
set
2
2
Kiln End Bag House Fan
set
1
3
Kiln Head Electric Dust Collecting Fan
set
1
4
Pulverized Coal Mill Ventilation Fan
set
1
5
Cement Raw Material Mill Recirculation Fan
set
2
6
Cement Mill Powder Dust Collecting Fan 
set
2

Amount

9

2016年10月30日星期日

Frequency Converter Application in Industrial Fans And Blowers by Xianrun Blower

Frequency Converter Application in Industrial Fans And Blowers by Xianrun Blower

Frequency converter is variable speed equipment of industrial production equipment for the three-phase ac motor, such as various fan equipment of product processing and manufacturing industry, ID fan, FD fan for boiler combustion system, cooling fans on the drying system, ventilation fan or exhaust fan for ventilation system, etc.
High Temperature Industrial ID Fans for Boilers

The most energy saving and power consumption are main fans in coal power plant.
Fan frequency converter controls and adjust fans according to furnace pressure, wind speed, air volume, temperature, and etc., to meet the technological requirements and operation condition.

In the past without frequency converter, the industrial fans control the airflow by controlling the adjusting door and baffle, and centrifugal fan motors has been running at maximum power condition regardless of the production size demand. 

In this case, not only production precision is restricted, but also causing a lot of energy waste and equipment loss, and leading to the production cost increases, shortening equipment service life, high maintenance cost to motor and mechanical transmission, and other electrical equipment.
Wear Resistant ID Fan

Most industrial fans and blowers use asynchronous motor and direct drive operation, so will cause large starting current, mechanical shock, electric protection features and so on. All these will affect the equipment service life, and it can not snap action protect equipment when there is mechanical failure, even pump damage and motor burning out. 

For the high power motor, no matter directly start or star triangle start, will have varying degrees impact on power grid, so State Grid Corporation of China regulation is that the large current devices are not allowed direct start.
High Temperature Fans for Dust Collecting

2016年9月26日星期一

The Features of Non Power Roof Ventilation Fan by Xianrun Blower

Non Power Roof Ventilation Fan Features by Xianrun Blower 

1. The curved blades have the best condition after scientific calculation, it can prevent rain and water intrusion during the working. The air exhausting efficiency is high, and the ventilation fan will operate lightly as long as the indoor and outdoor temperature difference is more than 0.5 Celsius degree.

Non Power Roof Ventilation Fan
2. Center shaft have detailed steps, which guarantee the fan blade will never be out of shape under high speed operation, and improve the ventilation fan service life. 

3. Changed diameter pipeline can make the ventilation fan easy to install in the slanting roof. The installation is very simple, ordinary people can finish the installation within 30 minutes. 
Non Power Roof Ventilation Fan
4. Saving money, reduce supporting cost, save electricity cost, and mounting cost, reduce noise.

5. Long service life, this model non power roof ventilation fan can work at least 10 years.

6. Free lubrication and maintenance.  

7. The material is stainless steel, and corrosion resistance. 

Non Power Roof Ventilation Fan

2016年9月23日星期五

Square Negative Pressure Fan Structure by Xianrun Blower

Square Negative Pressure Fan Structure By Xianrun Blower

1. Fan chassis: Frame and shutter are manufactured by galvanized plate material mold;

2. Fan blades: One-time stamping molding blades, fastening by screw, the computer precision balance calibration;
Large Airflow Axial Fan for Ventilation

3. Shutter: Shutter adapting pieces are made by high strength plastic steel, closed tightly, long service life, with the features of dust proof and water proof under the non-use state;

4. Motor: IP 44 or IP 54 high quality copper wire motor, generally it has two kinds, 380 V and 220 V;

5. Belt: Common rubber v-belts;

Large Airflow Axial Fan for Ventilation
6. Air guide sleeve: Guiding the air to air outlet, then discharged outside intensively;

7. Protection guard: Security guard to prevent manpower or foreign body into the fan;

8. Belt pulley: Transforming the motor speed into low speed by the sizes of the belt, reducing the noise of the fan operation and motor load.
Large Airflow Axial Fan for Ventilation

2016年9月22日星期四

Application Places Of Square Negative Pressure Fan

Square Negative Pressure Fan Application Places by Xianrun Blower

1. High temperature or smelly workshop, such as heat treatment plant, casting factory, plastics factory, aluminum plant, shoe factory, leather factory, electroplate factory, and all kinds of chemical plant.

Large Airflow Axial Fan for Ventilation
2. Labor-intensive enterprises, such as garment factories, all kinds of assemblies workshop, Internet bar.

3. Gardening, greenhouses, chicken farm, pig farm, cattle farm, and all types livestock farms ventilation and cooling.
Large Airflow Axial Fan for Ventilation
4. The Places need cooling and certain humidity. Such as cotton mill, woolen mill, flax textile factory, weaving mill, chemical fiber factory, warp knitting factory, texturing factory, knitting mill, silk factory, socks factory and other kinds of textile mills.

5. Warehousing logistics fields, all kinds warehouse, and logistics park. 

Large Airflow Axial Fan for Ventilation